TY - JOUR
T1 - The relation between fungal propagules in indoor air and home characteristics
AU - Ren, Ping
AU - Jankun, T. M.
AU - Belanger, K.
AU - Bracken, M. B.
AU - Leaderer, B. P.
PY - 2001
Y1 - 2001
N2 - Background: Questionnaires are commonly used in epidemiologic studies to obtain information about house characteristics in order to predict the household aeroallergen exposure levels. However, the reliability of the predictions made with the questionnaires has not been evaluated. To address this issue, we compared objectively measured fungal propagules including the most frequently isolated mold genera (i.e., Alternaria, Aspergillus, Cladosporium, Penicillium, etc.) in a large sample of homes and compared these measured values to the questionnaire-determined household characteristics. Methods: As part of a prospective cohort study on the relation between residential allergen exposure and development of asthma in neonates, fungal air samples were collected from infant bedrooms and main living areas in 1000 homes in the Northeast USA, from December 1996 to January 1999. A Burkard portable air sampler was used in combination with DG-18 and MEA agars. A questionnaire was used to obtain information on host and house characteristics that may have an impact on the presence of fungal propagules in the air. This included information on observation of moisture problems (e.g., water leakage or damage, and mold or mildew growth), ventilation and heating facilities, building age and type, number of occupants, annual household income, presence of pets and pests, cleaning regimens, etc. Results: The number of CFU/m3 air collected on MEA was significantly higher than on DG-18 (means, respectively, 1033.5 and 846.0 CFU/m3) (P < 0.0005). However, there was no significant difference between the numbers of CFU/m3 air collected from the main living area and from the infant bedroom. There was only a very weak relationship between the house characteristics, as described by questionnaire, and the presence of fungal propagules in indoor air. Only the temperature, relative humidity, season, and cats inside homes had a statistically significant impact on the presence of fungal propagules in indoor air. Conclusions: The presence of fungal propagules in indoor air cannot be reliably predicted by home characteristics. Actual measurements are required for fungal exposure assessment, and the use of only one medium to collect samples in one location in a home might be adequate to represent residential levels of fungi in indoor air.
AB - Background: Questionnaires are commonly used in epidemiologic studies to obtain information about house characteristics in order to predict the household aeroallergen exposure levels. However, the reliability of the predictions made with the questionnaires has not been evaluated. To address this issue, we compared objectively measured fungal propagules including the most frequently isolated mold genera (i.e., Alternaria, Aspergillus, Cladosporium, Penicillium, etc.) in a large sample of homes and compared these measured values to the questionnaire-determined household characteristics. Methods: As part of a prospective cohort study on the relation between residential allergen exposure and development of asthma in neonates, fungal air samples were collected from infant bedrooms and main living areas in 1000 homes in the Northeast USA, from December 1996 to January 1999. A Burkard portable air sampler was used in combination with DG-18 and MEA agars. A questionnaire was used to obtain information on host and house characteristics that may have an impact on the presence of fungal propagules in the air. This included information on observation of moisture problems (e.g., water leakage or damage, and mold or mildew growth), ventilation and heating facilities, building age and type, number of occupants, annual household income, presence of pets and pests, cleaning regimens, etc. Results: The number of CFU/m3 air collected on MEA was significantly higher than on DG-18 (means, respectively, 1033.5 and 846.0 CFU/m3) (P < 0.0005). However, there was no significant difference between the numbers of CFU/m3 air collected from the main living area and from the infant bedroom. There was only a very weak relationship between the house characteristics, as described by questionnaire, and the presence of fungal propagules in indoor air. Only the temperature, relative humidity, season, and cats inside homes had a statistically significant impact on the presence of fungal propagules in indoor air. Conclusions: The presence of fungal propagules in indoor air cannot be reliably predicted by home characteristics. Actual measurements are required for fungal exposure assessment, and the use of only one medium to collect samples in one location in a home might be adequate to represent residential levels of fungi in indoor air.
KW - Fungal propagules
KW - House characteristics
KW - Indoor air
KW - Seasonal variation
UR - http://www.scopus.com/inward/record.url?scp=0034999423&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034999423&partnerID=8YFLogxK
U2 - 10.1034/j.1398-9995.2001.056005419.x
DO - 10.1034/j.1398-9995.2001.056005419.x
M3 - Article
C2 - 11350305
AN - SCOPUS:0034999423
SN - 0105-4538
VL - 56
SP - 419
EP - 424
JO - Allergy: European Journal of Allergy and Clinical Immunology
JF - Allergy: European Journal of Allergy and Clinical Immunology
IS - 5
ER -