Abstract
A 68-year-old female underwent coronary angiogram which was complicated by guidewire entrapment in a deployed left anterior descending (LAD) artery stent that extended into the aorta. Snare loop technique was utilized to retrieve the entrapped guidewire and LAD stent with successful deployment of a new stent. Snaring technique is a unique method for percutaneous extraction and can be utilized with whole stent removal along with the guidewire. This technique, as outlined in our case, can be a safe and effective approach.
Original language | English (US) |
---|---|
Pages (from-to) | 118-121 |
Number of pages | 4 |
Journal | Cardiology Research |
Volume | 13 |
Issue number | 2 |
DOIs | |
State | Published - Apr 2022 |
Externally published | Yes |
Keywords
- Coronary guidewire complications
- Entrapped coronary guidewire
- Percutaneous coronary intervention complications
ASJC Scopus subject areas