TY - JOUR
T1 - Saline-Air Hysterosalpingo-Contrast Sonography Is Equivalent to the Modified Hysterosalpingogram following Hysteroscopic Sterilization
AU - Luong, Emerly
AU - Ludwin, Artur
AU - Winter, Thomas
AU - Yaklic, Jerome
AU - Maxwell, Rose A.
AU - Bhagavath, Bala
AU - Lindheim, Steven R.
N1 - Publisher Copyright:
© Wolters Kluwer Health, Inc. All rights reserved.
PY - 2020
Y1 - 2020
N2 - Purpose To estimate the diagnostic efficacy of saline-air hysterosalpingo-contrast sonography (SA-HyCoSy) compared with the modified hysterosalpingogram (mHSG) for confirmation of both coil location and tubal occlusion following hysteroscopic sterilization. Methods This study included 19 women who underwent both SA-HyCoSy and mHSG where 1 test was followed by the other. Sensitivity, specificity, and positive and negative predictive values for tubal occlusion against the mHSG were calculated for each fallopian tube by 2 independent interpreters. Interrater reliability was assessed using Cohen ? statistic. Procedure time and pain level by 11-point numeric rating scale of SA-HyCoSy and mHSG were also compared. Results Thirty-eight fallopian tubes were evaluated. Tubal occlusion was noted in 97.3% of tubes for both interpreters with the mHSG compared with 92.1% and 94.7% with SA-HyCoSy. The positive and negative predictive values for tubal occlusion were 100%/100% and 50%/33%, respectively, with an overall agreement of 97.4% and 95.7%, ? = 0.48, P < 0.01. Saline-air HyCoSy changed interpretation of coil insert location in 50% and 44.7% for each interpreter, being downgraded from optimal to satisfactory in 42.9% (9/21) and 36% (9/25) and upgraded to optimal in 58.8% (10/17) and 61.5% (8/13), respectively. There were no statistically significant differences in procedural time (7.5 vs 9.4 minutes, P > 0.05) or maximum pain scores (2.3 vs 3.1, P > 0.05) for the mHSG compared with SA-HyCoSy. Conclusions Our findings revealed a high degree of diagnostic accuracy with SA-HyCoSy for tubal occlusion, although coil location changed in nearly half of cases. Avoidance of radiation and patient convenience/compliance with SA-HyCoSy may outweigh the drawbacks.
AB - Purpose To estimate the diagnostic efficacy of saline-air hysterosalpingo-contrast sonography (SA-HyCoSy) compared with the modified hysterosalpingogram (mHSG) for confirmation of both coil location and tubal occlusion following hysteroscopic sterilization. Methods This study included 19 women who underwent both SA-HyCoSy and mHSG where 1 test was followed by the other. Sensitivity, specificity, and positive and negative predictive values for tubal occlusion against the mHSG were calculated for each fallopian tube by 2 independent interpreters. Interrater reliability was assessed using Cohen ? statistic. Procedure time and pain level by 11-point numeric rating scale of SA-HyCoSy and mHSG were also compared. Results Thirty-eight fallopian tubes were evaluated. Tubal occlusion was noted in 97.3% of tubes for both interpreters with the mHSG compared with 92.1% and 94.7% with SA-HyCoSy. The positive and negative predictive values for tubal occlusion were 100%/100% and 50%/33%, respectively, with an overall agreement of 97.4% and 95.7%, ? = 0.48, P < 0.01. Saline-air HyCoSy changed interpretation of coil insert location in 50% and 44.7% for each interpreter, being downgraded from optimal to satisfactory in 42.9% (9/21) and 36% (9/25) and upgraded to optimal in 58.8% (10/17) and 61.5% (8/13), respectively. There were no statistically significant differences in procedural time (7.5 vs 9.4 minutes, P > 0.05) or maximum pain scores (2.3 vs 3.1, P > 0.05) for the mHSG compared with SA-HyCoSy. Conclusions Our findings revealed a high degree of diagnostic accuracy with SA-HyCoSy for tubal occlusion, although coil location changed in nearly half of cases. Avoidance of radiation and patient convenience/compliance with SA-HyCoSy may outweigh the drawbacks.
KW - Essure
KW - hysterosalpingo-contrast sonography
KW - hysterosalpingogram
KW - hysteroscopic sterilization
UR - http://www.scopus.com/inward/record.url?scp=85086355727&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85086355727&partnerID=8YFLogxK
U2 - 10.1097/RUQ.0000000000000488
DO - 10.1097/RUQ.0000000000000488
M3 - Article
C2 - 32511207
AN - SCOPUS:85086355727
SN - 0894-8771
VL - 36
SP - 138
EP - 145
JO - Ultrasound Quarterly
JF - Ultrasound Quarterly
IS - 2
ER -