Abstract
In an attempt to allow physiologic expansion of the pulmonary autograft, yet limit late root dilation, we used stretch Gore-Tex material (W. L. Gore & Assoc, Flagstaff, AZ) as an external wrap. Follow-up cardiac computed tomography with reconstructed three-dimensional and dynamic images confirmed normal "triple bulge" sinus Valsalva geometry and preserved natural systolic expansion of the neoaortic root.
Original language | English (US) |
---|---|
Pages (from-to) | e34-e36 |
Journal | Annals of Thoracic Surgery |
Volume | 88 |
Issue number | 4 |
DOIs | |
State | Published - Oct 2009 |
ASJC Scopus subject areas
- Surgery
- Pulmonary and Respiratory Medicine
- Cardiology and Cardiovascular Medicine