Abstract
Rotational deformity following intramedullary nailing may cause symptoms and require surgical correction by osteotomy. Reamed, locked intramedullary nailing may be performed, but concern about cortical blood supply and potential pulmonary dysfunction from reaming have led many surgeons to limit this and use smaller diameter nails. Slotted nails are commonly used but are less stiff in torsion than the newer unslotted nails, particularly at the lower diameters. We report two cased of recurrent femoral rotational deformity after using statically interlocked slotted intramedullary nails to correct existing femoral rotational deformities. These patients show that small diameter statically interlocked femoral nails with diminished bone-nail contact must be stiff enough in rotation to avoid potential recurrence.
Original language | English (US) |
---|---|
Pages (from-to) | 4-8 |
Number of pages | 5 |
Journal | Journal of Bone and Joint Surgery - Series B |
Volume | 79 |
Issue number | 1 |
DOIs | |
State | Published - Jan 1997 |
Externally published | Yes |
ASJC Scopus subject areas
- Surgery