TY - JOUR
T1 - Osteoporosis risk assessment and ethnicity
T2 - Validation and comparison of 2 clinical risk stratification instruments
AU - Cass, Alvah R.
AU - Shepherd, Angela J.
AU - Carlson, Carol A.
N1 - Funding Information:
We would like to acknowledge the research support we received from the General Clinical Research Center at the University of Texas Medical Branch and from a grant from the Joint Grant Awards Council of the American Academy of Family Physicians Foundation. In addition, we would like to acknowledge Valarie Sidlo, Alma Salazar, April Moreno, and Brian Davis for their assistance with the primary data collection.
PY - 2006/6
Y1 - 2006/6
N2 - BACKGROUND: Dual energy x-ray absorptiometry (DXA), coupled with early treatment, may reduce morbidity and mortality associated with osteoporosis. Clinical tools to enhance selection of women for DXA screening have not been developed or validated in an ethnically diverse population. OBJECTIVE: To compare the performance of the osteoporosis risk assessment instrument (ORAI) and the simple calculated osteoporosis risk estimation (SCORE) instrument across 3 racial/ethnic groups to identify women who would benefit from DXA scans. DESIGN: Blinded comparison of the instruments in a cross-sectional sample. PARTICIPANTS: Two-hundred twenty-six postmenopausal women were recruited from a university-based family medicine clinic. Women with a prior diagnosis of osteoporosis or those taking bone active medications were excluded. MEASUREMENTS: Participants completed a questionnaire that contained the ORAI and the SCORE questions; 203 completed a DXA scan. RESULTS: The sensitivity and specificity for the ORAI (0.68, [0.49 to 0.88, 95% CI]; 0.66, [0.59 to 0.73, 95% CI]) and the SCORE instrument (0.54, [0.34 to 0.75, 95% CI]; 0.72, [0.65 to 0.78, 95% CI]) differed significantly from previous reports. Overall, the accuracy of the ORAI (66.5%) and SCORE instrument (70.0%) were similar (McNemar's test P value =.37). The accuracy between instruments differed significantly in African-American women (McNemar's test, P value <.001). In African Americans, the SCORE instrument correctly identified more women without osteoporosis, but missed 70% of those with osteoporosis. CONCLUSIONS: The performance of the ORAI and SCORE instrument differed significantly from previous reports. Although both can reduce the use of DXA scans for screening for osteoporosis, lower sensitivities resulted in underrecognition of osteoporosis and may limit their clinical usefulness in an ethnically diverse population.
AB - BACKGROUND: Dual energy x-ray absorptiometry (DXA), coupled with early treatment, may reduce morbidity and mortality associated with osteoporosis. Clinical tools to enhance selection of women for DXA screening have not been developed or validated in an ethnically diverse population. OBJECTIVE: To compare the performance of the osteoporosis risk assessment instrument (ORAI) and the simple calculated osteoporosis risk estimation (SCORE) instrument across 3 racial/ethnic groups to identify women who would benefit from DXA scans. DESIGN: Blinded comparison of the instruments in a cross-sectional sample. PARTICIPANTS: Two-hundred twenty-six postmenopausal women were recruited from a university-based family medicine clinic. Women with a prior diagnosis of osteoporosis or those taking bone active medications were excluded. MEASUREMENTS: Participants completed a questionnaire that contained the ORAI and the SCORE questions; 203 completed a DXA scan. RESULTS: The sensitivity and specificity for the ORAI (0.68, [0.49 to 0.88, 95% CI]; 0.66, [0.59 to 0.73, 95% CI]) and the SCORE instrument (0.54, [0.34 to 0.75, 95% CI]; 0.72, [0.65 to 0.78, 95% CI]) differed significantly from previous reports. Overall, the accuracy of the ORAI (66.5%) and SCORE instrument (70.0%) were similar (McNemar's test P value =.37). The accuracy between instruments differed significantly in African-American women (McNemar's test, P value <.001). In African Americans, the SCORE instrument correctly identified more women without osteoporosis, but missed 70% of those with osteoporosis. CONCLUSIONS: The performance of the ORAI and SCORE instrument differed significantly from previous reports. Although both can reduce the use of DXA scans for screening for osteoporosis, lower sensitivities resulted in underrecognition of osteoporosis and may limit their clinical usefulness in an ethnically diverse population.
KW - Cross-cultural medical issues
KW - Diagnosis
KW - Osteoporosis
KW - Women's health
UR - http://www.scopus.com/inward/record.url?scp=33744481283&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33744481283&partnerID=8YFLogxK
U2 - 10.1111/j.1525-1497.2006.00459.x
DO - 10.1111/j.1525-1497.2006.00459.x
M3 - Article
C2 - 16808748
AN - SCOPUS:33744481283
SN - 0884-8734
VL - 21
SP - 630
EP - 635
JO - Journal of general internal medicine
JF - Journal of general internal medicine
IS - 6
ER -