T1 - Noninvasive assessment of the hydration gradient across the cornea using confocal raman spectroscopy
AU - Bauer, Noël J.C.
AU - Wicksted, James P.
AU - Jongsma, Franciscus H.M.
AU - March, Wayne F.
AU - Hendrikse, Fred
AU - Motamedi, Massoud
PY - 1998/4
Y1 - 1998/4
N2 - PURPOSE. The feasibility of Raman spectroscopy for the noninvasive assessment of axial corneal hydration was investigated. METHODS. A scanning confocal Raman spectroscopy system, with an axial resolution of 50 μm, was used to assess noninvasively the water (OH-bond) to protein (CH-bond) ratio as a measure of the hydration in collagen-based phantom media and rabbit corneas. RESULTS. Raman spectra with high signal-to-noise ratios were obtained under in vitro and in vivo conditions within a range of corneal hydration (H = 0.0-8.3 mg water/mg dry wt). The Raman intensity ratio OH/CH showed a strong correlation with the hydration of the phantom medium (R2 > 0.99) and the rabbit corneas (R2 > 0.95). A degree of reproducibility was seen in measurements performed at a specific depth within the cornea (SD = 1.2%-2.7%). Quantitatively, the spatially resolved corneal water content, as assessed with our method, showed an increasing gradient from the anterior to the posterior region, with a difference of approximately 0.9. Significant qualitative differences in the axial hydration gradient were observed between the in vitro and in vivo situation, caused by the presence of an intact tear- film in vivo. Characterization of the axial corneal hydration using Raman spectroscopy provided a reliable estimation of total corneal hydration compared with conventional measurements using pachymetry and lyophilization. CONCLUSIONS. The proposed noninvasive confocal Raman spectroscopic technique has the potential to assess the axial corneal water gradient with a degree of sensitivity and reproducibility.
AB - PURPOSE. The feasibility of Raman spectroscopy for the noninvasive assessment of axial corneal hydration was investigated. METHODS. A scanning confocal Raman spectroscopy system, with an axial resolution of 50 μm, was used to assess noninvasively the water (OH-bond) to protein (CH-bond) ratio as a measure of the hydration in collagen-based phantom media and rabbit corneas. RESULTS. Raman spectra with high signal-to-noise ratios were obtained under in vitro and in vivo conditions within a range of corneal hydration (H = 0.0-8.3 mg water/mg dry wt). The Raman intensity ratio OH/CH showed a strong correlation with the hydration of the phantom medium (R2 > 0.99) and the rabbit corneas (R2 > 0.95). A degree of reproducibility was seen in measurements performed at a specific depth within the cornea (SD = 1.2%-2.7%). Quantitatively, the spatially resolved corneal water content, as assessed with our method, showed an increasing gradient from the anterior to the posterior region, with a difference of approximately 0.9. Significant qualitative differences in the axial hydration gradient were observed between the in vitro and in vivo situation, caused by the presence of an intact tear- film in vivo. Characterization of the axial corneal hydration using Raman spectroscopy provided a reliable estimation of total corneal hydration compared with conventional measurements using pachymetry and lyophilization. CONCLUSIONS. The proposed noninvasive confocal Raman spectroscopic technique has the potential to assess the axial corneal water gradient with a degree of sensitivity and reproducibility.
UR - http://www.scopus.com/inward/record.url?scp=0031977706&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031977706&partnerID=8YFLogxK
M3 - Article
C2 - 9538892
AN - SCOPUS:0031977706
SN - 0146-0404
VL - 39
SP - 831
EP - 835
JO - Investigative Ophthalmology and Visual Science
JF - Investigative Ophthalmology and Visual Science
IS - 5
ER -