TY - JOUR
T1 - Imaging liver transplantation candidates using gadolinium enhanced MDCT angiography
AU - Kantarci, Mecit
AU - Durur Subaşi, Irmak
AU - Aydinli, Bülent
AU - Duran, Cihan
AU - Doǧanay, Selim
AU - Yalçin Polat, K.
AU - Kantarci, Ragibe
AU - Oǧul, Hayri
AU - Atamanalp, S. Selçuk
PY - 2009/12
Y1 - 2009/12
N2 - Aim: To report our experience with gadolinium enhanced computed tomography angiography (Gd-CTA) for end-stage liver disease patients who are candidates for liver transplantation as an alternative to iodinated contrast enhanced CTA and gadolinium enhanced magnetic resonance (MR) angiography. Materials and methods: Seventeen patients with end-stage liver disease were evaluated with Gd-CTA. The patients were 10 men (58.8%) and 7 women (41.1%) (age range: 37-59 years). Multidetector CT (MDCT) was performed using 16-detector-row CT scanners. 3D images of the celiac artery, superior mesenteric artery, portal vein, and inferior vena cava (IVC) were obtained for thorough assessment using multiple plane reconstruction and maximum-intensity projection. Adequate images were defined by complete opacification of the celiac, superior mesenteric, hepatic propria, bilateral hepatic arteries, main portal vein and bilateral intrahepatic portal branches, and IVC. Results: All 17 Gd-CTAs were rated as diagnostic. Adequate CT arteriography (celiac, common hepatic, hepatic propia, and bilateral hepatic artery) and portography were obtained in all the patients. Engorged gastric and coronary varices were detected in 5 patients (29.4%). Severe splenorenal shunt was found in 2 patients (11.7%). Thrombus of the portal vein was observed in 3 patients (17.6%). The radiological findings and operational findings were not discordant in any of the operated patients. Conclusion: The degree of enhancement and image quality achieved using these gadolinium-enhanced MDCT angiographies appear adequate for angiographic evaluation of liver transplantation. Therefore, the use of 3D Gd-CTA in selected cases and settings can be advantageous in the pretransplantation evaluation.
AB - Aim: To report our experience with gadolinium enhanced computed tomography angiography (Gd-CTA) for end-stage liver disease patients who are candidates for liver transplantation as an alternative to iodinated contrast enhanced CTA and gadolinium enhanced magnetic resonance (MR) angiography. Materials and methods: Seventeen patients with end-stage liver disease were evaluated with Gd-CTA. The patients were 10 men (58.8%) and 7 women (41.1%) (age range: 37-59 years). Multidetector CT (MDCT) was performed using 16-detector-row CT scanners. 3D images of the celiac artery, superior mesenteric artery, portal vein, and inferior vena cava (IVC) were obtained for thorough assessment using multiple plane reconstruction and maximum-intensity projection. Adequate images were defined by complete opacification of the celiac, superior mesenteric, hepatic propria, bilateral hepatic arteries, main portal vein and bilateral intrahepatic portal branches, and IVC. Results: All 17 Gd-CTAs were rated as diagnostic. Adequate CT arteriography (celiac, common hepatic, hepatic propia, and bilateral hepatic artery) and portography were obtained in all the patients. Engorged gastric and coronary varices were detected in 5 patients (29.4%). Severe splenorenal shunt was found in 2 patients (11.7%). Thrombus of the portal vein was observed in 3 patients (17.6%). The radiological findings and operational findings were not discordant in any of the operated patients. Conclusion: The degree of enhancement and image quality achieved using these gadolinium-enhanced MDCT angiographies appear adequate for angiographic evaluation of liver transplantation. Therefore, the use of 3D Gd-CTA in selected cases and settings can be advantageous in the pretransplantation evaluation.
KW - Candidates
KW - Gadolinium
KW - Liver transplantation
KW - MDCT angiography
UR - http://www.scopus.com/inward/record.url?scp=73649126584&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=73649126584&partnerID=8YFLogxK
U2 - 10.3906/sag-0902-16
DO - 10.3906/sag-0902-16
M3 - Article
AN - SCOPUS:73649126584
SN - 1300-0144
VL - 39
SP - 909
EP - 916
JO - Turkish Journal of Medical Sciences
JF - Turkish Journal of Medical Sciences
IS - 6
ER -