Abstract
IgM, IgA, and IgG Rheumatoid Factors (RF) were measured by ELISA assay in serum from 26 patients with definite rheumatoid arthritis (RA) and 11 normal controls. IgM-RF was assayed by ELISA, radioimmunoassay,and also by the standard latex fixation test in all sera from RA patients. In patients with RA quantitative amounts of IgM, IgA, and IgG-RF as estimated by ELISA were highly correlated. Significant correlations were found between a physician's rating of disease activity and IgG-RF (r=0.44; p<.02) and IgA-RF (r=0.38; p=.06 but not for IgM-RF as measured in any of the three assays.
Original language | English (US) |
---|---|
Pages (from-to) | 392-398 |
Number of pages | 7 |
Journal | Clinical Rheumatology |
Volume | 4 |
Issue number | 4 |
DOIs | |
State | Published - Dec 1985 |
Externally published | Yes |
Keywords
- ELISA
- Radioimmunoassay
- Rheumatoid Factors
ASJC Scopus subject areas
- Rheumatology