Horizontal deployment of an intracranial stent via an antegrade approach for coil embolization of a basilar apex aneurysm: Technical note

Parham Yashar, Peter T. Kan, Elad I. Levy

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

The treatment of basilar apex aneurysms has progressively become more minimalistic in nature. Although initial coil embolizations were geared towards those aneurysms with a favorable neck to dome ratio, wide necked aneurysms have also been increasingly treated by the endovascular route. Several techniques have been described in the stent assisted coiling of basilar apex aneurysms, including the Y stent formation, waffle cone technique and horizontal stenting. Thus far, horizontal stenting has required access from a retrograde approach - namely, the posterior communicating artery. The authors describe a novel antegrade technique, through the basilar artery, for the deployment of a Neuroform-EZ stent (Boston Scientific, Natick, Massachusetts, USA) in a horizontal configuration across the neck of a basilar apex aneurysm. This approach allowed for the complete coil embolization of a wide necked basilar apex aneurysm.

Original languageEnglish (US)
Pages (from-to)355-357
Number of pages3
JournalJournal of neurointerventional surgery
Volume3
Issue number4
DOIs
StatePublished - Dec 2011
Externally publishedYes

ASJC Scopus subject areas

  • Surgery
  • Clinical Neurology

Fingerprint

Dive into the research topics of 'Horizontal deployment of an intracranial stent via an antegrade approach for coil embolization of a basilar apex aneurysm: Technical note'. Together they form a unique fingerprint.

Cite this