TY - JOUR
T1 - Feasibility of transanal total mesorectal excision (taTME) using the Medrobotics Flex® System
AU - Carmichael, Heather
AU - D’Andrea, Anthony P.
AU - Skancke, Matthew
AU - Obias, Vincent
AU - Sylla, Patricia
N1 - Publisher Copyright:
© 2019, Springer Science+Business Media, LLC, part of Springer Nature.
PY - 2020/1/1
Y1 - 2020/1/1
N2 - Background: The use of transanal total mesorectal excision (taTME) for treatment of rectal cancer is growing, but anatomic constraints prevent access to the proximal rectum with rigid instruments. The articulated instrumentation of current surgical robots is promising in overcoming these limitations, but the bulky size of current platforms inhibits the proximal reach of dissection. Flexible robotic systems could overcome these constraints while maintaining a stable platform for dissection. The goal of this study was to evaluate feasibility of performing taTME using the semi-robotic Flex® System (Medrobotics Corp., Raynham, MA) in human cadavers. Methods: taTME was performed by two surgeons in six fresh human cadaveric specimens using the Flex® System, with or without transabdominal laparoscopic assistance. Both mid- and low-rectal lesions were simulated. Metrics including quality of visualization, maintenance of pneumorectum, maneuverability of instruments, effectiveness of pursestring suture placement, and dissection in an anatomically correct plane were evaluated. Results: The semi-robotic endoluminal platform allowed for excellent visualization, insufflation, and dissection during taTME. Adequate pursestring occlusion of the rectum was achieved in all six cases. In cadavers with simulated mid-rectal lesions (N = 4), dissection and anterior peritoneal entry was achieved in all cases, with abdominal assistance utilized in two of four cases. In cadavers with simulated low-rectal lesions (N = 2), dissection was incomplete and aborted due to difficulty maneuvering instruments in close proximity to the rigid transanal port. Conclusions: Use of the Flex® system for taTME is feasible for mid-rectal dissection. Advantages over the traditional multi-armed robot include longer reach of instruments with the ability to dissect up to 17 cm from the anal verge, as well as tactile feedback. The current design of the flexible platform does not permit safe dissection in the distal rectum, although this constraint may be resolved with future adjustments to the equipment.
AB - Background: The use of transanal total mesorectal excision (taTME) for treatment of rectal cancer is growing, but anatomic constraints prevent access to the proximal rectum with rigid instruments. The articulated instrumentation of current surgical robots is promising in overcoming these limitations, but the bulky size of current platforms inhibits the proximal reach of dissection. Flexible robotic systems could overcome these constraints while maintaining a stable platform for dissection. The goal of this study was to evaluate feasibility of performing taTME using the semi-robotic Flex® System (Medrobotics Corp., Raynham, MA) in human cadavers. Methods: taTME was performed by two surgeons in six fresh human cadaveric specimens using the Flex® System, with or without transabdominal laparoscopic assistance. Both mid- and low-rectal lesions were simulated. Metrics including quality of visualization, maintenance of pneumorectum, maneuverability of instruments, effectiveness of pursestring suture placement, and dissection in an anatomically correct plane were evaluated. Results: The semi-robotic endoluminal platform allowed for excellent visualization, insufflation, and dissection during taTME. Adequate pursestring occlusion of the rectum was achieved in all six cases. In cadavers with simulated mid-rectal lesions (N = 4), dissection and anterior peritoneal entry was achieved in all cases, with abdominal assistance utilized in two of four cases. In cadavers with simulated low-rectal lesions (N = 2), dissection was incomplete and aborted due to difficulty maneuvering instruments in close proximity to the rigid transanal port. Conclusions: Use of the Flex® system for taTME is feasible for mid-rectal dissection. Advantages over the traditional multi-armed robot include longer reach of instruments with the ability to dissect up to 17 cm from the anal verge, as well as tactile feedback. The current design of the flexible platform does not permit safe dissection in the distal rectum, although this constraint may be resolved with future adjustments to the equipment.
KW - Natural orifice transluminal endoscopic surgery (NOTES)
KW - Proctectomy
KW - Rectal cancer
KW - Robotic surgery
KW - Robotic transanal total mesorectal excision
KW - Transanal total mesorectal excision (taTME)
UR - http://www.scopus.com/inward/record.url?scp=85069749200&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85069749200&partnerID=8YFLogxK
U2 - 10.1007/s00464-019-07019-y
DO - 10.1007/s00464-019-07019-y
M3 - Article
C2 - 31350608
AN - SCOPUS:85069749200
SN - 0930-2794
VL - 34
SP - 485
EP - 491
JO - Surgical Endoscopy
JF - Surgical Endoscopy
IS - 1
ER -