Abstract
Introduction: Living donor evaluation involves imaging to determine the choice of kidney for nephrectomy. Our aim was to study the diagnostic accuracy and correlation between CT-based volume measurements and split renal function (SRF) as measured by nuclear renography in potential living donors and its impact on kidney selection decision. Methods: We analyzed 190 CT-based volume measurements in healthy donors, of which 65 donors had a radionuclide study performed to determine SRF. Results: There were no differences in demographics, anthropometric measurements, total volumes, eGFR, creatinine clearances between those who required a nuclear scan and those who did not. There was a significant correlation between CT-volume-measurement-based SRF and nuclear-scan-based SRF (Pearson coefficient r 0.59; p < 0.001). Furthermore, selective nuclear-based SRF allowed careful selection of donor nephrectomy, leaving the donor with the higher functioning kidney in most cases. There was also a significantly higher number of right-sided nephrectomies selected after nuclear-based SRF studies. Conclusion: CT-based volume measurements in living donor imaging have sufficient correlation with nuclear-based SRF. Selective use of nuclear-scan-based SRF allows careful selection for donor nephrectomy.
Original language | English (US) |
---|---|
Pages (from-to) | 675-682 |
Number of pages | 8 |
Journal | Clinical Transplantation |
Volume | 28 |
Issue number | 6 |
DOIs | |
State | Published - Jun 2014 |
Externally published | Yes |
Keywords
- CT
- Kidney transplantation
- Kidney volume
- Living donor
- Nuclear renography
- Split renal function
ASJC Scopus subject areas
- Transplantation