TY - JOUR
T1 - Correction methods for noncontact intraocular pressure measurement in patients with keratoconus and healthy individuals
AU - Alvani, Azam
AU - Hashemi, Hassan
AU - Pakravan, Mohammad
AU - Yaseri, Mehdi
AU - Jafarzadehpur, Ebrahim
AU - Fotouhi, Akbar
N1 - Publisher Copyright:
© This content is licensed under a Creative Commons Attributions 4.0 International License.
PY - 2022
Y1 - 2022
N2 - Purpose: The objective of this study was to investigate the usefulness of four different algorithms to correct noncontact intraocular pressure measurement errors in keratoconus patients and normal individuals. Methods: Noncorrected intraocular pressure and corrected intraocular pressures were measured in one eye of 34 patients with keratoconus and 34 age- and gender-matched healthy controls using Corvis Scheimpflug Technology. The correlation of noncorrected intraocular pressure and corrected intraocular pressures with age, axial length, corneal shape, thickness, and biomechanics was calculated. Corrected intraocular pressures were compared with noncorrected intraocular pressure using paired t test and Bland-Altman plots (95% limits of agreement). Results: The noncorrected intraocular pressure correlated with corneal thickness and biomechanical parameters in both groups (all p≤0.047), and front and back mean keratometry in the keratoconus group (r=-0.39, p=0.02, and r=0.39, p=0.02, respectively). After adjustment with different intraocular pressure correction algorithms, biomechanically corrected intraocular pressure showed a minimal correlation with corneal features and a nonsignificant difference with noncorrected intraocular pressure in the healthy group (-0.1 ± 1.1 mmHg, p=0.58; 95% limits of agreement: -2.3 to 2.1 mmHg). Conclusions: Measuring intraocular pressure using noncontact tonometry and its corrected forms with a corneal thickness-based simple linear formula in patients with keratoconus is associated with many errors. Using more complex formulas that take into consideration more corneal stiffness parameters in addition to corneal thickness, such as biomechanically corrected intraocular pressure formula, may be more reliable and beneficial in this group of patients.
AB - Purpose: The objective of this study was to investigate the usefulness of four different algorithms to correct noncontact intraocular pressure measurement errors in keratoconus patients and normal individuals. Methods: Noncorrected intraocular pressure and corrected intraocular pressures were measured in one eye of 34 patients with keratoconus and 34 age- and gender-matched healthy controls using Corvis Scheimpflug Technology. The correlation of noncorrected intraocular pressure and corrected intraocular pressures with age, axial length, corneal shape, thickness, and biomechanics was calculated. Corrected intraocular pressures were compared with noncorrected intraocular pressure using paired t test and Bland-Altman plots (95% limits of agreement). Results: The noncorrected intraocular pressure correlated with corneal thickness and biomechanical parameters in both groups (all p≤0.047), and front and back mean keratometry in the keratoconus group (r=-0.39, p=0.02, and r=0.39, p=0.02, respectively). After adjustment with different intraocular pressure correction algorithms, biomechanically corrected intraocular pressure showed a minimal correlation with corneal features and a nonsignificant difference with noncorrected intraocular pressure in the healthy group (-0.1 ± 1.1 mmHg, p=0.58; 95% limits of agreement: -2.3 to 2.1 mmHg). Conclusions: Measuring intraocular pressure using noncontact tonometry and its corrected forms with a corneal thickness-based simple linear formula in patients with keratoconus is associated with many errors. Using more complex formulas that take into consideration more corneal stiffness parameters in addition to corneal thickness, such as biomechanically corrected intraocular pressure formula, may be more reliable and beneficial in this group of patients.
KW - Cornea
KW - Corneal pachymetry
KW - Intraocular pressure
KW - Keratoconus
KW - Noncontact tonometry
UR - http://www.scopus.com/inward/record.url?scp=85139880508&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85139880508&partnerID=8YFLogxK
U2 - 10.5935/0004-2749.20220072
DO - 10.5935/0004-2749.20220072
M3 - Article
C2 - 35170629
AN - SCOPUS:85139880508
SN - 0004-2749
VL - 85
SP - 490
EP - 497
JO - Arquivos Brasileiros de Oftalmologia
JF - Arquivos Brasileiros de Oftalmologia
IS - 5
ER -