T1 - Bubble formation during pulsed laser ablation
T2 - Laser-Tissue Interaction IV
AU - Leeuwen, Ton G.
AU - Jansen, E. D.
AU - Motamedi, Massoud
AU - Welch, Ashley J.
AU - Borst, Cornelius M.D.
PY - 1993
Y1 - 1993
N2 - Holmium (λ = 2.09 μm) and excimer (λ = 308 nm) lasers are used for ablation of tissue. In a previous study it was demonstrated that both excimer and holmium laser pulses produce fast expanding and collapsing vapor bubbles. To investigate whether the excimer induced bubble is caused by vaporization of water, the threshold fluence for bubble formation at a bare fiber tip in water was compared between the excimer laser (pulse length 115 ns) and the Q-switched and free-running holmium lasers (pulse length 1 μs to 250 μs, respectively). To induce bubble formation by excimer laser light in water, the absorber oxybuprocaine-hydrochloride (OBP-HCl) was added to the water. Fast flash photography was used to measure the threshold fluence as a function of the water temperature (6 - 90°C) at environmental pressure. The ultraviolet excimer laser light is strongly absorbed by blood. Therefore, to document the implications of bubble formation at fluences above the tissue ablation threshold, excimer laser pulses were delivered in vitro in hemoglobin solution and in vivo in the femoral artery of the rabbit. We conclude that the principal content of the fast bubble induced by a 308 nm excimer laser pulse is water vapor. Therefore, delivery of excimer laser pulses in a water or blood environment will cause fast expanding water vapor bubbles, which may induce mechanical damage to adjacent tissue.
AB - Holmium (λ = 2.09 μm) and excimer (λ = 308 nm) lasers are used for ablation of tissue. In a previous study it was demonstrated that both excimer and holmium laser pulses produce fast expanding and collapsing vapor bubbles. To investigate whether the excimer induced bubble is caused by vaporization of water, the threshold fluence for bubble formation at a bare fiber tip in water was compared between the excimer laser (pulse length 115 ns) and the Q-switched and free-running holmium lasers (pulse length 1 μs to 250 μs, respectively). To induce bubble formation by excimer laser light in water, the absorber oxybuprocaine-hydrochloride (OBP-HCl) was added to the water. Fast flash photography was used to measure the threshold fluence as a function of the water temperature (6 - 90°C) at environmental pressure. The ultraviolet excimer laser light is strongly absorbed by blood. Therefore, to document the implications of bubble formation at fluences above the tissue ablation threshold, excimer laser pulses were delivered in vitro in hemoglobin solution and in vivo in the femoral artery of the rabbit. We conclude that the principal content of the fast bubble induced by a 308 nm excimer laser pulse is water vapor. Therefore, delivery of excimer laser pulses in a water or blood environment will cause fast expanding water vapor bubbles, which may induce mechanical damage to adjacent tissue.
UR - http://www.scopus.com/inward/record.url?scp=0027266529&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0027266529&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:0027266529
SN - 0819411094
T3 - Proceedings of SPIE - The International Society for Optical Engineering
SP - 13
EP - 22
BT - Proceedings of SPIE - The International Society for Optical Engineering
PB - Publ by Society of Photo-Optical Instrumentation Engineers
Y2 - 18 January 1993 through 20 January 1993
ER -