TY - GEN
T1 - Automated assessment of postural stability system
AU - Napoli, Alessandro
AU - Ward, Christian R.
AU - Glassd, Stephen M.
AU - Tucker, Carole
AU - Obeid, Iyad
N1 - Publisher Copyright:
© 2016 IEEE.
PY - 2016/10/13
Y1 - 2016/10/13
N2 - The Balance Error Scoring System (BESS) is one of the most commonly used clinical tests to evaluate static postural stability deficits resulting from traumatic brain events and musculoskeletal injury. This test requires a trained operator to visually assess balance and give the subject a performance score based on the number of balance 'errors' they committed. Despite being regularly used in several real-world situations, the BESS test is scored by clinician observation and is therefore (a) potentially susceptible to biased and inaccurate test scores and (b) cannot be administered in the absence of a trained provider. The purpose of this research is to develop, calibrate and field test a computerized version of the BESS test using low-cost commodity motion tracking technology. This 'Automated Assessment of Postural Stability' (AAPS) system will quantify balance control in field conditions. This research goal is to overcome the main limitations of both the commercially available motion capture systems and the standard BESS test. The AAPS system has been designed to be operated by a minimally trained user and it requires little set-up time with no sensor calibration necessary. These features make the proposed automated system a valuable balance assessment tool to be utilized in the field.
AB - The Balance Error Scoring System (BESS) is one of the most commonly used clinical tests to evaluate static postural stability deficits resulting from traumatic brain events and musculoskeletal injury. This test requires a trained operator to visually assess balance and give the subject a performance score based on the number of balance 'errors' they committed. Despite being regularly used in several real-world situations, the BESS test is scored by clinician observation and is therefore (a) potentially susceptible to biased and inaccurate test scores and (b) cannot be administered in the absence of a trained provider. The purpose of this research is to develop, calibrate and field test a computerized version of the BESS test using low-cost commodity motion tracking technology. This 'Automated Assessment of Postural Stability' (AAPS) system will quantify balance control in field conditions. This research goal is to overcome the main limitations of both the commercially available motion capture systems and the standard BESS test. The AAPS system has been designed to be operated by a minimally trained user and it requires little set-up time with no sensor calibration necessary. These features make the proposed automated system a valuable balance assessment tool to be utilized in the field.
UR - http://www.scopus.com/inward/record.url?scp=85009080361&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85009080361&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2016.7592118
DO - 10.1109/EMBC.2016.7592118
M3 - Conference contribution
C2 - 28269642
AN - SCOPUS:85009080361
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 6090
EP - 6093
BT - 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2016
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2016
Y2 - 16 August 2016 through 20 August 2016
ER -