T1 - An Ambulatory Pulmonary and Right Heart Assist Device (OxyRVAD) in an Ovine Survival Model
AU - Wang, Dongfang
AU - Zhou, Xiaoqin
AU - Lick, Scott D.
AU - Liu, Xiaojun
AU - Qian, Kunxi
AU - Zwischenberger, Joseph B.
N1 - Funding Information:
Supported in part by a NIH STTR Grant #5 R42 HL067523 and Shriners Hospital of North America Grant #8700, and contracts with MC3 Corp, Ann Arbor, Michigan.
PY - 2007/10
Y1 - 2007/10
N2 - Background: To develop ambulatory total respiratory and right heart assistance for up to 4 weeks as a bridge to lung transplantation, we coupled a compact gas exchange device with a right ventricular assist device (RVAD), a compact rotary blood pump, to create an "OxyRVAD.". Methods: Our ambulatory OxyRVAD includes a portable (4 × 4 × 7-cm) centrifugal pump with heparin saline-purged needle roller bearings and an ultra-low-resistant gas exchange device (BioLung, MC3, Ann Arbor, MI). In 6 anesthetized sheep, the main pulmonary artery (PA) and right atrium (RA) were exposed through a left fourth intercostal thoracotomy. A 12-mm outer diameter vascular graft was anastomosed (end-to-side) to the main PA, and a VAD atrial cannula was placed into RA through the RA appendage. The pump and gas exchange device were interposed in circuit for RA-PA support. Results: All 6 sheep survived OxyRVAD insertion. Four sheep survived the 5-day experiment. One was euthanized at 48 hours owing to pump electrical failure (wiring) and another at 72 hours owing to pump bearing failure (broken heparin purge line). One sheep needed replacement of a BioLung due to internal thrombi. OxyRVAD flow was stable (range, 3.57-4.30 liters/min). Carbon dioxide removal was constant during experiment (range, 88.35 ± 6.12 ml/min at onset to 141.38 ± 5.48 ml/min at the 96th hour). Oxygen transfer decreased from 161.8 ± 8.8 to 79.7 ± 31.4 ml/min at the 96th hour (p = 0.045). Conclusion: Our ambulatory OxyRVAD provided total assistance of right heart and lungs in normal awake sheep for up to 5 days.
AB - Background: To develop ambulatory total respiratory and right heart assistance for up to 4 weeks as a bridge to lung transplantation, we coupled a compact gas exchange device with a right ventricular assist device (RVAD), a compact rotary blood pump, to create an "OxyRVAD.". Methods: Our ambulatory OxyRVAD includes a portable (4 × 4 × 7-cm) centrifugal pump with heparin saline-purged needle roller bearings and an ultra-low-resistant gas exchange device (BioLung, MC3, Ann Arbor, MI). In 6 anesthetized sheep, the main pulmonary artery (PA) and right atrium (RA) were exposed through a left fourth intercostal thoracotomy. A 12-mm outer diameter vascular graft was anastomosed (end-to-side) to the main PA, and a VAD atrial cannula was placed into RA through the RA appendage. The pump and gas exchange device were interposed in circuit for RA-PA support. Results: All 6 sheep survived OxyRVAD insertion. Four sheep survived the 5-day experiment. One was euthanized at 48 hours owing to pump electrical failure (wiring) and another at 72 hours owing to pump bearing failure (broken heparin purge line). One sheep needed replacement of a BioLung due to internal thrombi. OxyRVAD flow was stable (range, 3.57-4.30 liters/min). Carbon dioxide removal was constant during experiment (range, 88.35 ± 6.12 ml/min at onset to 141.38 ± 5.48 ml/min at the 96th hour). Oxygen transfer decreased from 161.8 ± 8.8 to 79.7 ± 31.4 ml/min at the 96th hour (p = 0.045). Conclusion: Our ambulatory OxyRVAD provided total assistance of right heart and lungs in normal awake sheep for up to 5 days.
UR - http://www.scopus.com/inward/record.url?scp=34848824000&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34848824000&partnerID=8YFLogxK
U2 - 10.1016/j.healun.2007.07.019
DO - 10.1016/j.healun.2007.07.019
M3 - Article
C2 - 17919615
AN - SCOPUS:34848824000
SN - 1053-2498
VL - 26
SP - 974
EP - 979
JO - Journal of Heart and Lung Transplantation
JF - Journal of Heart and Lung Transplantation
IS - 10
ER -